{"id":11279,"date":"2025-06-30T08:51:33","date_gmt":"2025-06-30T12:51:33","guid":{"rendered":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/?p=11279"},"modified":"2025-06-25T11:28:31","modified_gmt":"2025-06-25T15:28:31","slug":"autofluorescence","status":"publish","type":"post","link":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/immuno-techniques\/autofluorescence\/","title":{"rendered":"Autofluorescence"},"content":{"rendered":"\n\n\n\t<div class=\"dkpdf-button-container\" style=\" text-align:right \">\n\n\t\t<a class=\"dkpdf-button\" href=\"\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/11279?pdf=11279\" target=\"_blank\"><span class=\"dkpdf-button-icon\"><i class=\"fa fa-file-pdf-o\"><\/i><\/span> Download PDF<\/a>\n\n\t<\/div>\n\n\n\n\n\n<style>.entry p, .entry ol{font-size: 1rem;}.entry h3{color:#009fe3;margin-top:0}.entry h4{color:#009453;margin-top:1.5rem}.entry h5{color: #003a5c; font-size: 1.05rem;margin-top:1.5rem;}.entry figure{margin:32px auto;border:1px solid #ccc}.entry figure img{width:100%;display:block;margin:0 auto}.entry figcaption{font-size:.875rem;line-height:1.35rem;padding:10px;color:#222}.entry .blog-tbl{margin:1rem auto;caption-side:bottom}.entry .blog-tbl td,.entry .blog-tbl th{padding:10px 9px;border:1px solid #00172b;text-align:left}.entry .blog-tbl td{border-color:#003a5c}.entry .blog-tbl th{background-color:#00172b;color:#fff;border-left-color:#fff;border-right-color:#fff}.entry .blog-tbl th p{color:#fff}.entry .blog-tbl th:first-of-type{border-left-color:#00172b}.entry .blog-tbl th:last-of-type{border-right-color:#00172b}.entry .blog-tbl p{text-align:left;margin:0}.entry .box-note{border:2px solid #009453;padding:12px;margin:1rem 0}.entry .box-note p{margin:0;padding:0}.entry .styled-list{list-style-type:none}.entry .styled-list li{margin-top:1rem;line-height:22px;font-size:1rem;}.entry .styled-list li::before{font-family:\"Font Awesome 5 Pro\";display:inline-block;content:\"\\f3c5\";-webkit-transform:rotate(-90deg);transform:rotate(-90deg);margin-left:-20px;margin-right:11px;font-size:.75rem;color:#ed7004;font-weight:600}.entry .styled-list ol li::before{display:none}.entry .styled-list li>ul li::before{font-weight:200}.entry .overview{width:-webkit-fit-content;width:-moz-fit-content;width:fit-content;padding:16px;margin:1rem auto;border:1px solid #eee}.entry .overview hr{margin-top:14px}.entry .overview-text{text-align:center;font-size:1rem;margin:0}.entry .btn-sq{color:#fff;font-size:.9rem;font-weight:600;border:2px solid rgb(237, 112, 4);padding:7px 13px;background:rgb(237, 112, 4);cursor:pointer;text-align:center;line-height:1.5rem;margin:0 auto;}.entry .btn-sq:hover{text-decoration:none;color:rgb(237, 112, 4);background:#fff;}.entry .btn-container{display:flex;width:100%;margin:1.3rem 0;}.entry .btn-container .fa-solid, .entry .btn-container .fa-duotone{margin-right:10px;}@media(max-width: 768px){.entry .btn-sq{font-size:1.05rem;}}<\/style>\n<style>.entry h4{margin-top: 2rem;}.entry ol li{line-height: 1.6rem;margin-top:1rem;}<\/style>\n<p><script src=\"https:\/\/kit.fontawesome.com\/904923013f.js\" crossorigin=\"anonymous\"><\/script><\/p>\n<div class=\"entry\">\n<h2>Autofluorescence can present challenges for techniques such as immunohistochemistry (IHC), immunocytochemistry (ICC), and flow cytometry, where it may reduce assay sensitivity by increasing background or may even mask the specific signal altogether. This article looks at some common causes of autofluorescence and suggests ways to minimize its impact.<\/h2>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-11038 size-full\" src=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/anti-gfp-hero.jpg\" alt=\"\" width=\"700\" height=\"169\" srcset=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/anti-gfp-hero.jpg 700w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/anti-gfp-hero-300x72.jpg 300w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/p>\n<h4>What is autofluorescence?<\/h4>\n<p>Autofluorescence is a term used to describe the background fluorescence observed in biological samples that does not result from staining with a specific fluorescent probe. It is most prominent in the green channel, where it can interfere with the signal from antibody-conjugated fluorophores such as Alexa Fluor\u00ae 488 and fluorescein isothiocyanate (FITC), potentially obscuring the detection of analytes with low abundance. In addition, autofluorescence can hamper the detection of green fluorescent protein (GFP), which is widely used as a fusion tag and as a quantitative reporter for gene expression.<\/p>\n<h4>Common sources of autofluorescence<\/h4>\n<p>Many endogenous sample components can autofluoresce. The following are some of the best-known examples:<\/p>\n<ul class=\"styled-list\">\n<li><strong>Collagen<\/strong> \u2013 the main component of the extracellular matrix (ECM)<\/li>\n<li><strong>Riboflavin (vitamin B2)<\/strong> \u2013 the precursor to flavin mononucleotide (FMN) and flavin adenine dinucleotide (FAD), which are coenzymes with essential roles in metabolism<\/li>\n<li><strong>NADH <\/strong>\u2013 the reduced form of nicotinamide adenine dinucleotide (NAD), a coenzyme primarily involved in the production of ATP through oxidative phosphorylation in mitochondria<\/li>\n<li><strong>Elastin<\/strong> \u2013 an ECM component responsible for the extensibility and elastic recoil of tissues, including blood vessels, lungs, and skin<\/li>\n<li><strong>Lipofuscin<\/strong> &#8211; a pigmented byproduct of intracellular catabolism that accumulates progressively over time in the lysosomes and cytosol of post-mitotic cells such as myocytes and neurons<\/li>\n<li><strong>Heme<\/strong> \u2013 an iron-protoporphyrin complex found in hemoproteins including hemoglobin, myoglobin, and cytochrome P450<\/li>\n<li><strong>Aromatic amino acids<\/strong> \u2013 phenylalanine, tryptophan, and tyrosine<\/li>\n<li><strong>Melanin<\/strong> \u2013 a pigment produced by melanocytes and found in the hair, skin, and iris, which protects against ultraviolet (UV) rays and reactive oxygen species (ROS)<\/li>\n<li><strong>Chlorophyll<\/strong> &#8211; a green pigment, found in plants and cyanobacteria, which absorbs light to provide energy for photosynthesis<\/li>\n<li><strong>Lignin<\/strong> &#8211; a complex heteropolymer found in plant cell walls<\/li>\n<\/ul>\n<p>In addition, autofluorescence can come from common laboratory reagents and consumables. These include the following:<\/p>\n<ul class=\"styled-list\">\n<li><strong>Plastic microplates and cell culture flasks<\/strong> \u2013 these should ideally be substituted with glass-bottomed or nonfluorescent polymer containers for fluorescence imaging studies<\/li>\n<li><strong>Media supplements <\/strong>\u2013 additives such as Fetal Bovine Serum (FBS) and Phenol Red should be avoided when performing live-cell imaging studies<\/li>\n<li><strong>Aldehyde fixatives<\/strong> &#8211; formaldehyde, paraformaldehyde, and glutaraldehyde can yield autofluorescence by reacting with amine groups to form Schiff\u2019s bases. To mitigate against this effect, samples can be fixed with an organic solvent such as ice-cold methanol. Alternatively, aldehyde-fixed samples can be treated with sodium borohydride, which is known to neutralize Schiff\u2019s bases by reducing amine-aldehyde compounds into non-fluorescent salts.<\/li>\n<\/ul>\n<h4>How to evaluate sample autofluorescence<\/h4>\n<p>To determine the level of autofluorescence present in a sample, researchers are advised to run an unstained control and observe the sample using available filter sets. This simply involves performing the experiment as per usual, but omitting the fluorescently-labeled reagent. If autofluorescence is detected, the experimental protocol may require optimization.<\/p>\n<h4>Ways to manage autofluorescence<\/h4>\n<p>Besides the methods previously described, many other approaches have been developed to reduce autofluorescence. Choosing which to use will depend on factors including the sample type, fixation method, and application being performed, but the following are some tried and tested strategies:<\/p>\n<ul class=\"styled-list\">\n<li>Select fluorophores that are spectrally distinct from any observed autofluorescence; for example, consider using a <a href=\"https:\/\/www.jacksonimmuno.com\/catalog\/23\">Near-Infrared (NIR) Fluorescent Conjugate<\/a> if autofluorescence is detected in the green channel<\/li>\n<li>Titrate fluorescent reagents to maximize the signal-to-background ratio<\/li>\n<li>If you&#8217;re using a GFP tag and finding background signal in the GFP channel you can try using an <a href=\"https:\/\/www.jacksonimmuno.com\/catalog\/58\">Anti-GFP Antibody Conjugate <\/a>\u00a0to switch detection away from the green channel<\/li>\n<\/ul>\n<figure><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-11287\" src=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/24-Q3-UNC-IF-af-647-af488-liver-Panel-1-and-2-300dpi-1024x448.jpg\" alt=\"\" width=\"700\" height=\"306\" srcset=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/24-Q3-UNC-IF-af-647-af488-liver-Panel-1-and-2-300dpi-1024x448.jpg 1024w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/24-Q3-UNC-IF-af-647-af488-liver-Panel-1-and-2-300dpi-300x131.jpg 300w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/24-Q3-UNC-IF-af-647-af488-liver-Panel-1-and-2-300dpi-1536x672.jpg 1536w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/24-Q3-UNC-IF-af-647-af488-liver-Panel-1-and-2-300dpi-2048x896.jpg 2048w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><figcaption><strong>Fig 1:<\/strong> Anti-GFP Antibodies can be used to distinguish genuine signal from autofluorescence that overlaps with the GFP tag signal.<\/figcaption><\/figure>\n<ul class=\"styled-list\">\n<li>For flow cytometry experiments, use a viability dye to gate out dead cells and debris that can exhibit high levels of autofluorescence.<\/li>\n<li>Remove red blood cells from tissue samples by perfusing with Phosphate Buffered Saline (not applicable to archived or post-mortem tissue), or from whole blood by performing a lysis step followed by washing<\/li>\n<li>Consider performing an autofluorescence-reducing treatment; for example, photobleaching samples prior to incubation with fluorescently-labeled antibodies, incubating samples overnight in 5% H<sub>2<\/sub>O<sub>2<\/sub>, or quenching autofluorescence with Sudan black B.<sup>1,2,3<\/sup><\/li>\n<li>Think about switching from traditional flow cytometry to spectral flow cytometry, or from conventional fluorescence microscopy to fluorescence lifetime imaging microscopy (FLIM), to allow for separating autofluorescence from immunofluorescence signals<sup>4,5<\/sup><\/li>\n<li>Always include relevant controls to ensure results are interpreted correctly<\/li>\n<\/ul>\n<p><em>Learn more about Anti-GFP Antibody Conjugates from Jackson ImmunoResearch in this <\/em><a href=\"https:\/\/www.jacksonimmuno.com\/technical\/products\/groups\/anti-gfp\"><em>Technical Note<\/em><\/a><em>, which includes links to application-specific case studies<\/em><\/p>\n<p><a href=\"\/technical\/products\/groups\/anti-gfp\"><img decoding=\"async\" style=\"width: 100%;\" src=\"\/secondary-antibody-resource\/wp-content\/uploads\/24-Q2-GFP-Ads-728x90-B.jpg\" alt=\"\" \/><\/a><\/p>\n<hr \/>\n<h4>References<\/h4>\n<ul class=\"styled-list\">\n<li>Sun Y, Ip P, Chakrabartty A. Simple Elimination of Background Fluorescence in Formalin-Fixed Human Brain Tissue for Immunofluorescence Microscopy. J Vis Exp. 2017;(127):56188. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/28892031\/\">doi:10.3791\/56188<\/a><\/li>\n<li>Willows JW, Blaszkiewicz M, Townsend KL. A clearing-free protocol for imaging intact whole adipose tissue innervation in mice. STAR Protoc. 2022;3(1):101109. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/35106499\/\">doi:10.1016\/j.xpro.2021.101109<\/a><\/li>\n<li>Sun Y, Yu H, Zheng D, <em>et al<\/em>. Sudan black B reduces autofluorescence in murine renal tissue. Arch Pathol Lab Med. 2011;135(10):1335-1342. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/21970489\/\">doi:10.5858\/arpa.2010-0549-OA<\/a><\/li>\n<li>Roet JEG, Mikula AM, de Kok M, et al. Unbiased method for spectral analysis of cells with great diversity of autofluorescence spectra. Cytometry A. 2024;105(8):595-606. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/38863410\/\">doi:10.1002\/cyto.a.24856<\/a><\/li>\n<li>Hwang W, McPartland T, Jeong S, Evans CL. A robust method for autofluorescence-free immunofluorescence using high-speed fluorescence lifetime imaging microscopy. Sci Rep. 2025;15(1):5503. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/39953137\/\">doi:10.1038\/s41598-025-89142-6<\/a><\/li>\n<\/ul>\n<\/div>\n<table class=\"table blogLinks\">\n<thead>\n<tr>\n<th class=\"span6\">Learn more:<\/th>\n<th class=\"span6\">Do more:<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"span6\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/directandindirectwesternblotting\/\">Indirect and direct Western blotting<\/a><\/td>\n<td class=\"span6\"><a href=\"https:\/\/jacksonimmuno.com\/home\/exhibitions\">Exhibition Schedule<\/a><\/td>\n<\/tr>\n<tr>\n<td class=\"span6\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/chemiluminescent-western-blotting\/\">Chemiluminescence western blotting<\/a><\/td>\n<td class=\"span6\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/western-blotting-guide\/\">Western blotting guide<\/a><\/td>\n<\/tr>\n<tr>\n<td class=\"span6\"><a class=\"row-title\" href=\"\/secondary-antibody-resource\/technical-tips\/expansionmicroscopy\/\">An Introduction to Expansion Microscopy<\/a><\/td>\n<td class=\"span6\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/elisa-guide\/\">ELISA guide<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- AddThis Advanced Settings generic via filter on the_content --><!-- AddThis Share Buttons generic via filter on the_content --><!-- AddThis Related Posts generic via filter on the_content -->","protected":false},"excerpt":{"rendered":"<p>Download PDF Autofluorescence can present challenges for techniques such as immunohistochemistry (IHC), immunocytochemistry (ICC), and flow cytometry, where it may reduce assay sensitivity by increasing background or may even mask the specific signal altogether. This article looks at some common causes of autofluorescence and suggests ways to minimize its impact. What is autofluorescence? Autofluorescence is [&hellip;]<!-- AddThis Advanced Settings generic via filter on get_the_excerpt --><!-- AddThis Share Buttons generic via filter on get_the_excerpt --><!-- AddThis Related Posts generic via filter on get_the_excerpt --><\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":""},"categories":[3,16],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/11279"}],"collection":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/comments?post=11279"}],"version-history":[{"count":18,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/11279\/revisions"}],"predecessor-version":[{"id":11411,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/11279\/revisions\/11411"}],"wp:attachment":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/media?parent=11279"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/categories?post=11279"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/tags?post=11279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}