{"id":126,"date":"2016-07-13T09:42:40","date_gmt":"2016-07-13T13:42:40","guid":{"rendered":"https:\/\/jir-us-test.rwscott.co.uk\/secondary-antibody-resource\/?p=126"},"modified":"2026-01-05T06:12:37","modified_gmt":"2026-01-05T11:12:37","slug":"fluorescent-western-blotting","status":"publish","type":"post","link":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/immuno-techniques\/fluorescent-western-blotting\/","title":{"rendered":"Fluorescent Western blotting"},"content":{"rendered":"\n\n\n\t<div class=\"dkpdf-button-container\" style=\" text-align:right \">\n\n\t\t<a class=\"dkpdf-button\" href=\"\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/126?pdf=126\" target=\"_blank\"><span class=\"dkpdf-button-icon\"><i class=\"fa fa-file-pdf-o\"><\/i><\/span> Download PDF<\/a>\n\n\t<\/div>\n\n\n\n\n\n<h2><b><\/b><span style=\"font-weight: 400;\">Fluorescent Western blotting can offer many advantages to an already robust protein detection technique. Secondary Antibodies are conjugated to a fluorescent dye such as an Alexa Fluor<sup>\u00ae<\/sup><\/span><span style=\"font-weight: 400;\">\u00a0to generate signal which can be detected using a digital imager. The technique is highly sensitive, can be used quantitatively and allows for multiplex detection on the same blot without stripping and reprobing.<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Like colorimetric and chemiluminescent Western blotting, fluorescent Western blotting uses the antigen-antibody complex to detect specific proteins immobilized on a blotting membrane after separation by electrophoresis. Visualization of the protein is achieved by exciting the fluorescent dye using an imaging system equipped with an appropriate light source<\/span><span style=\"font-weight: 400;\">. <\/span><span style=\"font-weight: 400;\">The fluorescent dye absorbs light at its excitation wavelength, and then releases photons at its emission wavelength to return the molecule to its ground electronic state. The light emitted by the fluorescent molecule (fluorophore) is then<\/span> <span style=\"font-weight: 400;\">detected by a digital imager equipped with the correct filters.<\/span><\/p>\n<div id=\"attachment_255\" style=\"width: 610px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-255\" decoding=\"async\" loading=\"lazy\" class=\"wp-image-255\" src=\"\/secondary-antibody-resource\/wp-content\/uploads\/flurowest-1024x390.png\" width=\"600\" height=\"229\" srcset=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/flurowest-1024x390.png 1024w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/flurowest-300x114.png 300w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/flurowest.png 1333w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><p id=\"caption-attachment-255\" class=\"wp-caption-text\"><em>Figure 1: Indirect Fluorescent detection. A. Fluorescent dye-conjugated secondary antibody detects the primary antibody for the protein of interest. B. Light is used to excite the fluorescent conjugate at its excitation wavelength. C. The excited fluorescent dye emits light at its emission wavelength which is detected via a digital imager, allowing visualization of the protein of interest.<\/em><\/p><\/div>\n<h4><b>Fluorescent Western blotting offers a number of advantages over chemiluminescent and colorimetric detection.<\/b><\/h4>\n<h5><b>Multiplex detection \u2013 detecting multiple proteins on a single blot.<\/b><\/h5>\n<p><span style=\"font-weight: 400;\">Fluorescent blotting makes multiplex Western blot analysis easily achievable,<\/span> <span style=\"font-weight: 400;\">as<\/span> <span style=\"font-weight: 400;\">multiple proteins can be simultaneously detected and differentiated on the same blot. Dye conjugated secondary antibodies directed against primaries raised in different species can be used to label each specific antigen<\/span> <span style=\"font-weight: 400;\">(protein) with a dye with its own individual emission wavelength \u2013 spectral characteristics. The spectrally distinct dyes are excited by the digital imager and emit light at their signature wavelengths, allowing two or three different proteins to be detected on the same blot (Figure 2). This offers advantages over chemiluminescent and colorimetric detection, which require stripping and reprobing the blot when looking at multiple targets. Fluorescent detection allows the blots to be used quantitatively because proteins on the blot are not perturbed by harsh stripping chemicals. Another benefit is the visualization of proteins that are poorly resolved by electrophoresis, as proteins that are not well separated by size can be distinguished by color. Jackson ImmunoResearch offers fluorescent dye-conjugated secondary antibodies that have minimal cross-reactivity with selected species, enabling detection of individual primary antibodies (and therefore target proteins) without signal overlap.<\/span><\/p>\n<div id=\"attachment_1178\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-1178\" decoding=\"async\" loading=\"lazy\" class=\"wp-image-1178 size-medium\" src=\"\/secondary-antibody-resource\/wp-content\/uploads\/NIR-western-1-e1485289972377-300x265.png\" width=\"300\" height=\"265\" srcset=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/NIR-western-1-e1485289972377-300x265.png 300w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/NIR-western-1-e1485289972377.png 588w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-1178\" class=\"wp-caption-text\"><em>Figure 2: Multiplex detection of multiple protein targets without stripping and reprobing. Double immunofluorescence staining on a Western blot using Alexa Fluor<sup>\u00ae<\/sup> 680 far-red dye and Alexa Fluor<sup>\u00ae<\/sup> 790 infrared dye. Mouse IgG was reduced and denatured with \u03b2-mercaptoethanol and SDS. The heavy and light chains were separated by SDS-PAGE, transferred to nitrocellulose, and double labeled with a 1:100,000 dilution of Alexa Fluor<sup>\u00ae<\/sup> 790-Goat anti-Mouse IgG, Fc\u03b3 Subclass 1 specific (min X Hu, Bov, Rb Sr Prot, 115-655-205) (green) detecting heavy chains at 50 kDa and a 1:100,000 dilution of Alexa Fluor<sup>\u00ae<\/sup> 680-Goat anti-Mouse IgG, light chain specific (min X Bov, Gt, Hrs, Hu, Rb, Rat, Shp Ig, 115-625-174) (red) detecting light chains at 25 kDa). Fluorescence was imaged in a LiCor Odyssey imager.<\/em><\/p><\/div>\n<h5><b>Quantitative<\/b><\/h5>\n<p><span style=\"font-weight: 400;\">The amount of signal produced is proportional to the amount of protein present. When combined with a wide dynamic range, optimized fluorescent Western blots can be used quantitatively, since both low and high abundance proteins can be detected on the same blot without saturating detection.<\/span><\/p>\n<h5><b>Sensitivity and robustness<\/b><\/h5>\n<p><span style=\"font-weight: 400;\">Far-red and infrared fluorescent dye conjugates such as Alexa Fluor<\/span><span style=\"font-weight: 400;\"><sup>\u00ae<\/sup><\/span><span style=\"font-weight: 400;\"> 680 and 790 (Figure 2) offer greater sensitivity due to low fluorescence quenching, high extinction coefficients and low background autofluorescence. They can be used for high sensitivity, quantitative and in-gel Western blotting as well as microWestern, in-cell and on-cell Western arrays and other techniques that require the brightest dyes. Due to good stability blots can potentially be archived and re-imaged.<\/span><\/p>\n<h5><b>Fluorescent Dot blotting<\/b><\/h5>\n<p><span style=\"font-weight: 400;\">A very simple and quick immunotechnique that can be used for optimizing detection limits and the screening of numerous samples is the dot blot. When migration of an analyte has already been characterized, dot-blotting is a fast and simple way to screen multiple samples for presence of the protein of interest. The use of a grid system allows detection sensitivity to be ascertained without the variability of transfer in multiple Western blots. Using fluorescent dyes it is possible to confirm presence of one or more analytes in sample on the same blot.<\/span><\/p>\n<div id=\"attachment_1179\" style=\"width: 460px\" class=\"wp-caption alignnone\"><img aria-describedby=\"caption-attachment-1179\" decoding=\"async\" loading=\"lazy\" class=\"wp-image-1179\" src=\"\/secondary-antibody-resource\/wp-content\/uploads\/af-488-dot-blot.jpg\" width=\"450\" height=\"284\" srcset=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/af-488-dot-blot.jpg 802w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/af-488-dot-blot-300x190.jpg 300w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><p id=\"caption-attachment-1179\" class=\"wp-caption-text\"><em>Figure 3: Fluorescent Dot blot. ChromPure Rabbit IgG (H+L) detected with Alexa Fluor<sup>\u00ae<\/sup> 488 Goat anti-Rabbit IgG (H+L). After application of protein the membrane was blocked using 5% Bovine Serum Albumin. 1 second exposure; filter 525; Blue LED module light; 3&#215;3 binning.<\/em><\/p><\/div>\n<table class=\"jirtable\" style=\"height: 637px;\" border=\"1\" width=\"699\" cellpadding=\"4\">\n<tbody>\n<tr>\n<th align=\"left\" bgcolor=\"#7F9CAD\">Fluorophore<\/th>\n<th bgcolor=\"#7F9CAD\">Excitation Peak (nm)<\/th>\n<th bgcolor=\"#7F9CAD\">Emission Peak (nm)<\/th>\n<\/tr>\n<tr>\n<td bgcolor=\"#5a00e1\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/dylight-405\">DyLight 405<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">400<\/td>\n<td align=\"CENTER\">421<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#5a00e1\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"http:\/\/www.jacksonimmuno.com\/technical\/products\/conjugate-selection\/brilliant-violet\/421\">Brilliant Violet 421\u2122<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">407<\/td>\n<td align=\"CENTER\">421<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#0066CC\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/amca\">Aminomethylcoumarin, AMCA<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">350<\/td>\n<td align=\"CENTER\">450<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#0000e1\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"http:\/\/www.jacksonimmuno.com\/technical\/products\/conjugate-selection\/brilliant-violet\/480\">Brilliant Violet 480\u2122<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">436<\/td>\n<td align=\"CENTER\">478<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#28e100\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/cyanine\/cy2\">Cyanine, Cy2<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">492<\/td>\n<td align=\"CENTER\">510<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#28e100\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/488\">Alexa Fluor<\/a><\/u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/488\"><sup>\u00ae<\/sup><\/a><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/488\"> 488<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">493<\/td>\n<td align=\"CENTER\">519<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#28e100\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/fitc\">Fluorescein, FITC\/DTAF<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">492<\/td>\n<td align=\"CENTER\">520<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e17c00\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/cyanine\/cy3\">Indocarbocyanine, Cy3<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">550<\/td>\n<td align=\"CENTER\">570<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e17c00\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/r-pe\">R-Phycoerythrin R-PE<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">many, 488<\/td>\n<td align=\"CENTER\">580<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e17c00\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/rrx\">Rhodamine Red-X, RRX<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">570<\/td>\n<td align=\"CENTER\">590<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e17c00\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/594\">Alexa Fluor<sup>\u00ae<\/sup> 594<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">591<\/td>\n<td align=\"CENTER\">614<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e10000\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/apc\">Allophycocyanin APC<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">many, 650<\/td>\n<td align=\"CENTER\">660<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e10000\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/647\">Alexa Fluor<sup>\u00ae<\/sup> 647<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">651<\/td>\n<td align=\"CENTER\">667<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e10000\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/cyanine\/cy5\">Indodicarbocyanine, Cy5<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">650<\/td>\n<td align=\"CENTER\">670<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e10000\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/percp\">Peridinin-Chlorophyll-protein PerCP<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">many, 488<\/td>\n<td align=\"CENTER\">675<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#e10000\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/680-790\">Alexa Fluor<sup>\u00ae<\/sup> 680<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">684<\/td>\n<td align=\"CENTER\">702<\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#6c0000\"><span style=\"color: #fff;\"><u><a style=\"color: #ffffff;\" href=\"\/technical\/products\/conjugate-selection\/alexa-fluor\/680-790\">Alexa Fluor<sup>\u00ae<\/sup> 790<\/a><\/u><\/span><\/td>\n<td align=\"CENTER\">792<\/td>\n<td align=\"CENTER\">803<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Table 1: <\/span><i><span style=\"font-weight: 400;\">Depending on the set-up of your digital imager fluorescent dyes ranging from ultraviolet to infrared may be compatible for use in fluorescent Western blotting. For multiplex detection it is important to select dyes that are spectrally distinct, with no overlapping spectra.<\/span><\/i><\/p>\n<h5><b>Things to remember<\/b><\/h5>\n<p><span style=\"font-weight: 400;\">Like chemiluminescent Western blotting, fluorescent blotting requires optimization to improve detection of signal over background noise. Background can come from materials used for blotting, so it is important to select materials that are do not have fluorescent properties. Polyacrylamide electrophoresis gels and blotting membranes (both nitrocellulose and PVDF) may have fluorescent properties which can cause significant background. <\/span><span style=\"font-weight: 400;\">Observe an unstained gel or membrane using various filter options available on the detection instrument, and if possible choose a fluorescent dye that emits light in a region \u00a0where the membrane doesn\u2019t autofluoresce.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Low signal may be due to low antigen (due to low protein expression, degradation or overzealous washing of the blotting membrane), and subsequent fluorescent labeling will be low, even with the amplification benefits of a secondary antibody. Signal can also be reduced due to fluorescence quenching, whereby the signal is diminished by F\u00f6rster resonance energy transfer (FRET), if the fluorescent labeling is too high. Digital imagers allow efficient optimization of detection conditions compared with chemiluminescent blotting, which requires repeated exposures to optimize.<\/span><br \/>\n<\/p>\n<table class=\"table blogLinks\">\n<thead>\n<tr>\n<th class=\"span6\">Learn more:<\/th>\n<th class=\"span6\">Do more:<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"span6\"><a href=\"\/technical\/products\/groups\/signal-enhancement\">Signal enhancement<\/a><\/td>\n<td class=\"span6\"><a href=\"\/catalog\/1\">Whole IgG affinity purified secondary antibodies<\/a><\/td>\n<\/tr>\n<tr>\n<td class=\"span6\"><a href=\"\/technical\/products\/protocols\/multiple-labeling\">Multiple labeling using conjugated secondary antibodies<\/a><\/td>\n<td class=\"span6\"><a href=\"\/catalog\/23\">Far red \u00a0and infrared fluorescent conjugates for Western blotting.<\/a><\/td>\n<\/tr>\n<tr>\n<td class=\"span6\"><a href=\"\/technical\/products\/conjugate-selection\/brilliant-violet\">BD\u00a0Brilliant Violet\u2122 dye conjugates<\/a><\/td>\n<td class=\"span6\"><a href=\"\/files\/JIR-Multiple-Labeling-Poster.pdf\">Download Multiple labeling poster<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5><br \/>\n<strong>References:<\/strong><\/h5>\n<p>Alberts B et al (1994) Molecular biology of the Cell. 3rd Ed. Garland press. London<\/p>\n<p>Roitt et al (2005) Immunology. 6th Ed. Mosby. Spain<\/p>\n<p>Silva JM, McMahon M. The Fastest Western in Town: A Contemporary Twist on the Classic Western Blot Analysis. <i>Journal of Visualized Experiments\u202f: JoVE<\/i>. 2014;(84):51149. doi:10.3791\/51149 (2014).<\/p>\n<!-- AddThis Advanced Settings generic via filter on the_content --><!-- AddThis Share Buttons generic via filter on the_content --><!-- AddThis Related Posts generic via filter on the_content -->","protected":false},"excerpt":{"rendered":"<p>Download PDF Fluorescent Western blotting can offer many advantages to an already robust protein detection technique. Secondary Antibodies are conjugated to a fluorescent dye such as an Alexa Fluor\u00ae\u00a0to generate signal which can be detected using a digital imager. The technique is highly sensitive, can be used quantitatively and allows for multiplex detection on the [&hellip;]<!-- AddThis Advanced Settings generic via filter on get_the_excerpt --><!-- AddThis Share Buttons generic via filter on get_the_excerpt --><!-- AddThis Related Posts generic via filter on get_the_excerpt --><\/p>\n","protected":false},"author":3,"featured_media":362,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":""},"categories":[3],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/126"}],"collection":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/comments?post=126"}],"version-history":[{"count":71,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/126\/revisions"}],"predecessor-version":[{"id":11497,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/126\/revisions\/11497"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/media\/362"}],"wp:attachment":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/media?parent=126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/categories?post=126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/tags?post=126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}