{"id":9401,"date":"2023-05-31T05:45:07","date_gmt":"2023-05-31T09:45:07","guid":{"rendered":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/?p=9401"},"modified":"2023-09-19T05:44:55","modified_gmt":"2023-09-19T09:44:55","slug":"elisa-guide-part-4-troubleshooting","status":"publish","type":"post","link":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/immuno-techniques\/elisa-guide-part-4-troubleshooting\/","title":{"rendered":"ELISA Guide; Part 4: Troubleshooting"},"content":{"rendered":"\n\n\n\t<div class=\"dkpdf-button-container\" style=\" text-align:right \">\n\n\t\t<a class=\"dkpdf-button\" href=\"\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/9401?pdf=9401\" target=\"_blank\"><span class=\"dkpdf-button-icon\"><i class=\"fa fa-file-pdf-o\"><\/i><\/span> Download PDF<\/a>\n\n\t<\/div>\n\n\n\n\n\n<style>.entry p, .entry ol{font-size: 1rem;}.entry h3{color:#009fe3;margin-top:0}.entry h4{color:#009453;margin-top:1.5rem}.entry h5{color: #003a5c; font-size: 1.05rem;margin-top:1.5rem;}.entry figure{margin:32px auto;border:1px solid #ccc}.entry figure img{width:100%;display:block;margin:0 auto}.entry figcaption{font-size:.875rem;line-height:1.35rem;padding:10px;color:#222}.entry .blog-tbl{margin:1rem auto;caption-side:bottom}.entry .blog-tbl td,.entry .blog-tbl th{padding:10px 9px;border:1px solid #00172b;text-align:left}.entry .blog-tbl td{border-color:#003a5c}.entry .blog-tbl th{background-color:#00172b;color:#fff;border-left-color:#fff;border-right-color:#fff}.entry .blog-tbl th p{color:#fff}.entry .blog-tbl th:first-of-type{border-left-color:#00172b}.entry .blog-tbl th:last-of-type{border-right-color:#00172b}.entry .blog-tbl p{text-align:left;margin:0}.entry .box-note{border:2px solid #009453;padding:12px;margin:1rem 0}.entry .box-note p{margin:0;padding:0}.entry .styled-list{list-style-type:none}.entry .styled-list li{margin-top:1rem;line-height:1rem;font-size:1rem;}.entry .styled-list li::before{font-family:\"Font Awesome 5 Pro\";display:inline-block;content:\"\\f3c5\";-webkit-transform:rotate(-90deg);transform:rotate(-90deg);margin-left:-20px;margin-right:11px;font-size:.75rem;color:#ed7004;font-weight:600}.entry .styled-list ol li::before{display:none}.entry .styled-list li>ul li::before{font-weight:200}.entry .overview{width:-webkit-fit-content;width:-moz-fit-content;width:fit-content;padding:16px;margin:1rem auto;border:1px solid #eee}.entry .overview hr{margin-top:14px}.entry .overview-text{text-align:center;font-size:1rem;margin:0}.entry .btn-sq{color:#fff;font-size:.9rem;font-weight:600;border:2px solid rgb(237, 112, 4);padding:7px 13px;background:rgb(237, 112, 4);cursor:pointer;text-align:center;line-height:1.5rem;margin:0 auto;}.entry .btn-sq:hover{text-decoration:none;color:rgb(237, 112, 4);background:#fff;}.entry .btn-container{display:flex;width:100%;margin:1.3rem 0;}.entry .btn-container .fa-solid, .entry .btn-container .fa-regular, .entry .btn-container .fa-duotone{margin-right:10px;}@media(max-width: 768px){.entry .btn-sq{font-size:1.05rem;}}<\/style>\n<style>.entry .styled-list li.nested-list::before {display: none;}.entry .styled-list li > ul li > ul li::before{content:\"\\f041\"}#contents h4 {margin-top: 15px;margin-bottom:14px;text-align:center;font-size:1.18rem}#contents {max-width:450px;margin-left:auto;margin-right:auto;}.entry h6{font-size:1rem;}<\/style>\n<p><script src=\"https:\/\/kit.fontawesome.com\/904923013f.js\" crossorigin=\"anonymous\"><\/script><\/p>\n<style>.entry img{width: 100%} .tbl-blue th{text-align:center}.entry .tbl-blue .row-color{background-color: #fde5d0;vertical-align: middle;width:35%;}.row-border{border-top: 1px solid #fff}.tbl-blue tbody tr:first-child{border-top-color: lime;}<\/style>\n<p><!--\n\n\n<h2>Lorem ipsum dolor sit amet, consectetur adipiscing elit. Etiam nisi nisl, faucibus vitae nunc vel, mattis tristique augue. Orci varius natoque penatibus et magnis dis parturient montes, nascetur ridiculus mus. Praesent convallis arcu nulla, vel aliquet ligula congue vel. Nam in eros vestibulum, gravida mi non, suscipit mauris.<\/h2>\n\n\n--><\/p>\n<div id=\"contents-container\">\n<div id=\"contents\">\n<div id=\"contents-inner\">\n<h4>Overview<\/h4>\n<hr>\n<ul id=\"cont-list\" class=\"styled-list\">\n<li><a href=\"#no-signal-or-weak-signal\">No Signal or Weak Signal<\/a><\/li>\n<li><a href=\"#high-background\">High Background<\/a><\/li>\n<li><a href=\"#poor-reproducibility-between-plates\">Poor Reproducibility Between Plates<\/a><\/li>\n<li><a href=\"#poor-reproducibility-between-runs\">Poor Reproducibility Between Runs<\/a><\/li>\n<li><a href=\"#edge-effects-plate-drift\">Edge Effects \/ Plate Drift<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<hr>\n<h4 id=\"troubleshooting\">ELISA Troubleshooting<\/h4>\n<p>Several common issues can occur when running an ELISA. These are detailed in the following table, along with suggested solutions.<\/p>\n<table id=\"no-signal-or-weak-signal\" class=\"tbl-blue\">\n<thead>\n<tr>\n<th colspan=\"2\">No signal or weak signal<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"row-color\" rowspan=\"4\">Capture antigen or antibody may not have adhered to the microplate<\/td>\n<\/tr>\n<tr>\n<td>Check the binding capacity of the microplate according to the manufacturer&#8217;s description<\/td>\n<\/tr>\n<tr>\n<td>Try using a different coating buffer<\/td>\n<\/tr>\n<tr>\n<td>Increase the incubation time for plate coating<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Concentration of analyte-specific antibodies may be too low<\/td>\n<td>Increase the concentration of the capture antibody and\/or the analyte-specific detection antibody<\/td>\n<\/tr>\n<tr>\n<td>Increase the incubation time for analyte-specific antibody binding<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Analyte-specific detection antibody and secondary antibody may be incompatible<\/td>\n<td>Confirm that the host species of the analyte-specific detection antibody is compatible with the secondary antibody (for example, if the analyte-specific detection antibody was raised in rabbit, an anti-rabbit secondary antibody is required for detection)<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"3\">Capture and detection antibodies may be competing for the same epitope (sandwich ELISA)<\/td>\n<td>Confirm that the capture and detection antibodies recognize different epitopes<\/td>\n<\/tr>\n<tr>\n<td>Switch to using a matched antibody pair if available<\/td>\n<\/tr>\n<tr>\n<td>Consider using a different ELISA format (e.g. try using an indirect ELISA that requires only one analyte-specific antibody rather than a sandwich ELISA)<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Fluorophore-conjugated antibodies may have been compromised by exposure to light<\/td>\n<td>Ensure fluorophore-conjugated antibodies are stored correctly<\/td>\n<\/tr>\n<tr>\n<td>Protect fluorophore-conjugated antibodies from light when adding them to, and incubating them in, the microplate wells<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">If only the standard wells (and not the sample wells) are affected, the standard may have degraded<\/td>\n<td>Try using a fresh vial of standard<\/td>\n<\/tr>\n<tr>\n<td>Check that the standard has been prepared and stored correctly<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Azide (often added to antibody storage buffers as a preservative ) may be inhibiting HRP activity<\/td>\n<td>Ensure sufficient washing to remove any residual traces of azide<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Sample material may contain only low levels of the target analyte<\/td>\n<td>Obtain more concentrated samples<\/td>\n<\/tr>\n<tr>\n<td>Spike samples with a known amount of analyte to check the sample matrix is not a source of interference<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">ELISA kits \/ kit components may have been stored incorrectly<\/td>\n<td>Check the manufacturer\u2019s instructions for storage<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Plate may have been read at an incorrect wavelength<\/td>\n<td>Check the reader settings are compatible with the chosen detection method<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"high-background\" class=\"tbl-blue\">\n<thead>\n<tr>\n<th colspan=\"2\">High Background<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"row-color\" rowspan=\"2\">Washing may be inadequate<\/td>\n<td>Increase the number and\/or duration of wash steps<\/td>\n<\/tr>\n<tr>\n<td>Try adding detergent (e.g. 0.01-0.1% Tween-20) to wash buffers<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"3\">Blocking may be insufficient<\/td>\n<td>Try using a more concentrated blocking solution<\/td>\n<\/tr>\n<tr>\n<td>Increase the incubation time for blocking<\/td>\n<\/tr>\n<tr>\n<td>Switch to using a different blocking buffer<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Sample may be too concentrated<\/td>\n<td>Try diluting the sample<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Antibody concentration(s) may be too high<\/td>\n<td>Decrease the concentration of the capture antibody, analyte-specific detection antibody, or secondary antibody<\/td>\n<\/tr>\n<tr>\n<td>Decrease the antibody incubation time<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Colorimetric substrates may have been prepared too early<\/td>\n<td>Always prepare substrates such as TMB immediately prior to use to avoid unwanted color development<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Microplates may have sat around after the addition of stop solution (colorimetric detection)<\/td>\n<td>Read colorimetric assays as soon as the stop solution has been added<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Consumables such as pipette tips, reservoirs or buffers may have introduced contamination<\/td>\n<td>Use fresh plasticware for each step<\/td>\n<\/tr>\n<tr>\n<td>Prepare fresh buffers for each assay<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Incubation times may have been too long<\/td>\n<td>Always follow the protocol and be consistent with reagent additions and timing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"poor-reproducibility-between-plates\" class=\"tbl-blue\">\n<thead>\n<tr>\n<th colspan=\"2\">Poor reproducibility between plates<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"row-color\" rowspan=\"3\">Plates may have been coated unevenly<\/td>\n<td>Ensure all solutions are thoroughly mixed before coating the plates<\/td>\n<\/tr>\n<tr>\n<td>Seal plates after adding the coating solution to prevent evaporation; such effects can especially be noticeable in edge wells<\/td>\n<\/tr>\n<tr>\n<td>Check pipettes have been calibrated and are performing as expected<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Washing may be inadequate<\/td>\n<td>Increase the number and\/or duration of wash steps<\/td>\n<\/tr>\n<tr>\n<td>Confirm wells are fully emptied between washes<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Wells may contain bubbles<\/td>\n<td>Centrifuge microplates briefly prior to reading<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Plate seals may be a source of cross-contamination<\/td>\n<td>Always use fresh plate seals between incubations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"poor-reproducibility-between-runs\" class=\"tbl-blue\">\n<thead>\n<tr>\n<th colspan=\"2\">Poor reproducibility between runs<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"row-color\" rowspan=\"2\">Reagents may have degraded<\/td>\n<td>Prepare fresh reagents (including buffers) for each assay<\/td>\n<\/tr>\n<tr>\n<td>Check that the standard has been prepared and stored correctly<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Samples may have been handled incorrectly<\/td>\n<td>Always store and handle samples with care and avoid repeat freeze-thawing<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Assay conditions may be inconsistent<\/td>\n<td>Ensure all protocol steps are performed reproducibly<\/td>\n<\/tr>\n<tr>\n<td>Always run ELISAs under stable environmental conditions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table id=\"edge-effects-plate-drift\" class=\"tbl-blue\">\n<thead>\n<tr>\n<th colspan=\"2\">Edge effects \/ plate drift<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"row-color\">The plate reader may be misaligned<\/td>\n<td>Read the plate, then rotate it by 180o and read again; if the effect remains in the same position, the reader may need to be repaired by a qualified service engineer<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Solutions may be cold<\/td>\n<td>Ensure all solutions are at room temperature upon addition to the microplate unless otherwise stated in the protocol<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Delays may have occurred during reagent addition<\/td>\n<td>Prepare suitable quantities of reagents (including dead volumes) for the assay to avoid running out part-way across a plate<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\" rowspan=\"2\">Volumes may be uneven across the microplate<\/td>\n<td>Seal plates between reagent additions to prevent evaporation<\/td>\n<\/tr>\n<tr>\n<td>Only use calibrated pipettes<\/td>\n<\/tr>\n<tr class=\"row-border\">\n<td class=\"row-color\">Plates may have cross-contaminated one another<\/td>\n<td>Avoid stacking plates during incubations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"btn-container\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/elisa-guide\/\" class=\"btn-sq\"><i class=\"fa-regular fa-chevrons-right\"><\/i>View previous parts of the ELISA guide<\/a><\/div>\n<p><a href=\"https:\/\/www.jacksonimmuno.com\/technical\/products\/groups\/anti-his\"><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter wp-image-9882 size-full\" src=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/Anti-His-Advert_600pxX100-2.jpg\" alt=\"\" width=\"600\" height=\"100\" srcset=\"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/Anti-His-Advert_600pxX100-2.jpg 600w, https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-content\/uploads\/Anti-His-Advert_600pxX100-2-300x50.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<table class=\"table blogLinks aligncenter\">\n<thead>\n<tr>\n<th class=\"span6\">Learn more:<\/th>\n<th class=\"span6\">Do more:<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"span6\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/colorimetric-western-blotting\/\">Colorimetric western blotting<\/a><\/td>\n<td class=\"span6\"><strong><a href=\"https:\/\/www.jacksonimmuno.com\/technical\/products\/conjugate-selection\/fluorophore-selection#spectra\">Spectra Viewer<\/a><\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"span6\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/fluorescent-western-blotting\/\">Chemiluminescence western blotting<\/a><\/td>\n<td class=\"span6\"><a href=\"\/technical\/products\/groups\/signal-enhancement\">Antibodies for signal enhancement<\/a><\/td>\n<\/tr>\n<tr>\n<td class=\"span6\" colspan=\"2\"><a href=\"\/secondary-antibody-resource\/immuno-techniques\/fluorescent-western-blotting\/\">Fluorescent western blotting<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- AddThis Advanced Settings generic via filter on the_content --><!-- AddThis Share Buttons generic via filter on the_content --><!-- AddThis Related Posts generic via filter on the_content -->","protected":false},"excerpt":{"rendered":"<p>Download PDF Overview No Signal or Weak Signal High Background Poor Reproducibility Between Plates Poor Reproducibility Between Runs Edge Effects \/ Plate Drift ELISA Troubleshooting Several common issues can occur when running an ELISA. These are detailed in the following table, along with suggested solutions. No signal or weak signal Capture antigen or antibody may [&hellip;]<!-- AddThis Advanced Settings generic via filter on get_the_excerpt --><!-- AddThis Share Buttons generic via filter on get_the_excerpt --><!-- AddThis Related Posts generic via filter on get_the_excerpt --><\/p>\n","protected":false},"author":14,"featured_media":10531,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":""},"categories":[3,16],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/9401"}],"collection":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/comments?post=9401"}],"version-history":[{"count":19,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/9401\/revisions"}],"predecessor-version":[{"id":10327,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/posts\/9401\/revisions\/10327"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/media\/10531"}],"wp:attachment":[{"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/media?parent=9401"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/categories?post=9401"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jacksonimmuno.com\/secondary-antibody-resource\/wp-json\/wp\/v2\/tags?post=9401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}